Elektr ishlashi
| BIRLIK | YH5WZ-26/66 | YH5WS-32/85 | YH5WR-34/90 | |
| Tizimning nominal kuchlanishi | KV | 35 | 35 | 35 |
| To'xtatuvchining nominal kuchlanishi | KV | 51 | 51 | 51 |
| Doimiy ish kuchlanishi | KV | 40.8 | 40.8 | 40.8 |
| Nominal tushirish oqimi | KA | 5 | 5 | 5 |
| DC 1mA mos yozuvlar kuchlanishi | ≥kV | 73 | 73 | 73 |
| 2mS kvadrat to'lqinli oqim hajmi | A | 400 | 600 | 800 |
| 4/10mS yuqori oqim ta'siriga chidamliligi | KA | 100 | 100 | 100 |
| Tik to'lqinlar qoldiq bosimga ta'sir qiladi | ≤kV | 134 | 134 | 134 |
| Chaqmoq zarbasi qoldiq kuchlanish | ≤kV | 114 | 114 | 114 |
| Ta'sir qoldiq bosimini ishlating | ≤kV | 154 | 154 | 154 |
| Rezistiv oqim (cho'qqi) | ≤mA | 120 | 130 | 150 |
| Umumiy oqim (cho'qqi) | ≤mA | 500 | 550 | 600 |