| Mahsulot tavsifi | |||
| Standart sertifikatlar | IEC60947-2 | ||
| Mahsulot raqami | M7400 | ||
| Qutblar soni | 3,.4 | ||
| IEC60947-2 va EN60947-2 standartlariga muvofiq elektr xususiyatlari | |||
| Nominal oqim Kirish | 250,300,315,350,400 | 450,500,550,600,630 | |
| Nominal ish kuchlanishi, Ue | AC: 415V | AC: 415V | |
| Nominal izolyatsiyalangan kuchlanish (Ui) | AC: 800V | AC: 800V | |
| Nominal impulsli kuchlanishga chidamlilik, Uimpl | 8kV | 8kV | |
| Eng yuqori sinish qobiliyati (kA rms Icu) | 220/240V | 75 | 75 |
| 380/400V | 50 | 50 | |
| 415V | 50 | 50 | |
| 550V | 20 | 20 | |
| Baholangan xizmat ko'rsatish buzilishi sig'im (kA rms Icu) | 220/240V | 50 | 50 |
| 380/400V | 35 | 35 | |
| 415V | 35 | 35 | |
| 550V | 13 | 13 | |
| Himoya funktsiyasi | Haddan tashqari yuklanish, qisqa tutashuv | Haddan tashqari yuklanish, qisqa tutashuv | |
| Sayohat birligi turi | Termal-magnit | Termal-magnit | |
| Magnit sayohat oralig'i | 400A | 400A | |
| Foydalanish toifasi | A | A | |
| Chidamlilik | Mexanik | 7000 ta operatsiya | 7000 ta operatsiya |
| Elektr | 3000 ta operatsiya | 3000 ta operatsiya | |
| Ulanish | Old ulanish | Old ulanish | |
| O'rnatish | Standart | Vintni mahkamlash | Vintni mahkamlash |
| O'lchamlari mm) | Qutb | ||
| 3 | 257×140×145 | 257x140×145 | |
| 4 | 257×185×145 | 257×185×145 | |
Eslatma: Eshikning kesish o'lchamiga qarab chuqurlik: katta kesish uchun cl, kichik kesish uchun c2.
| A | A1 | B | B2 | F1 | F2 | F3 |
| 127.5 | 257 | 70 | 182 | 45 | 22.5 | 90 |